Stranded loose tube, gel-free cable, iRP-increased rodent protected, universal-u - eCatalog

eCatalog

Stranded loose tube, gel-free cable, iRP-increased rodent protected, universal-use, UV.FRLSZH sheath - yellow, Cca, 8 x 12f = 96 fibers G657A1

Article no.: R878469
EAN / GTIN: 7611821012566
Delivery Unit: 1
Unit of Measure: M

Gel-free, improved rodent-protected and longitudinal watertight stranded non-metallic loose tube cable with up to 96 fibers in a 8-strand stranding, for indoor or outdoor duct installation (universal-use).

Technical Data
Cable family code UTd8x2,3GF FiRis
Cable type Stranded loose tube cable
Cable version Gel-free installation cable
Cable application universal use
CPR classification Cca-s2,d1,a1
DoP number D9090
Fiber type Singlemode ITU-T G.657.A1
Fiber count 96
Fiber color coding 1.-12.: red, green, blue, yellow, white, gray, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 8
Loose tube diameter 2.3 mm
FRP/coat. CSM nominal thickness [mm] 2.5 / 3.9
Armor powerful rodent protected
Outer sheath thickness 1.4 mm
Outer sheath color yellow
Sheath marking Ink-Jet, black
Cable outer diameter 12.5 mm
Cable weight 155.0 kg/km / 104 lbs/1000ft
DIN / VDE 0888 code U-BQ(ZN)BH nx2,3
Warranty R&Mfreenet
Expected lifetime min. 30 years
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2100 m ± 5%
CPR classification Cca
Minimum bending radius no tension - 10 x cable diameter
Mechanical Data
In-service tensile strength 2500 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1A
Installation tensile strength 5000 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1A
Crush resistance long term 2000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 4000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=20 x cable diameter, 25 cycles
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 185 mm
Minimum bend radius during installation 250 mm
Loose-tube colour coding 1. red, 2. green - on each layer, rest of tubes white, fillers black
Environmental Characteristics
Temperature cycling 40 °C 70 °C / +104 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Operation temperature 40 °C to 70 °C / +104 °F to +158 °F
Storage / Transport temperature 40 °C to 70 °C / +104 °F to +158 °F
Water penetration L = 3 m, h = 1 m, 24 h
Water penetration acceptance criteria no water leakage
Water penetration test method IEC 60794-1-22 F5B
Thermal load 2.2 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Flammability vertical cable bundle Pass
Flammability vertical cable bundle test method IEC 60332-3-22
Smoke density Pass
Smoke density test method IEC 61034-1, IEC 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method IEC 60754-2
2015 / 863 / EU - RoHS 3 conform