Central loose tube, gel-free cable, iRP-increased rodent protected, universal-use, UV.FRLSZH sheath - turquoise, Cca, 01 x 08 fibers OM3

Article no.: R870414
EAN / GTIN: 7611821014638
Delivery Unit: 1
Unit of Measure: M

Central loose tube cable (CLT) for up to a maximum of 12 fibers. Non-metallic,“intensified” rodent protected (IRP) and gel-free (dry) for indoor or outdoor duct installation (universal-use).

Technical Data
Cable family code UTd1GF FiRis
Cable type Central loose tube cable
Cable version Gel-free installation cable
Cable application universal use
CPR classification Cca-s1a,d0,a1
DoP number D9088
Fiber type OM3
Fiber count 8
Fiber color coding 1.-12.: red, green, blue, yellow, white, gray, brown, violet, turquoise, black, orange, pink
Fiber count per tube 12
Loose tube count 1
Loose tube diameter 2.8 mm
Armor Rodent protection
Outer sheath thickness 1.2 mm
Outer sheath material UV stable FRLSZH
Outer sheath color turquoise/aqua
Cable outer diameter 6.8 mm
Cable weight 32.0 kg/km / 21 lbs/1000ft
DIN / VDE 0888 code U-BQ(ZN)BH
Warranty R&Mfreenet
CPR test method EN 50575, EN 13501-6
Standard put-up length on drum 2’100 m ± 5%
CPR classification Cca
Minimum bending radius no tension - 10 x cable diameter
Mechanical Data
In-service tensile strength 1000 N
In-service tensile strength acceptance criteria Δα ≤ 0,05 dB
In-service tensile strength test method IEC 60794-1-21:E1
Installation tensile strength 2000 N
Installation tensile strength acceptance criteria Δα ≤ 0,05 dB after test
Installation tensile strength test method IEC 60794-1-21:E1
Crush resistance long term 2000 N/100mm
Long-term crush resistance acceptance criteria Δα ≤ 0,05 dB prior release, no damage
Long-term crush resistance test method IEC 60794-1-21:E3A
Short-term crush resistance 4000 N/100mm
Short-term crush resistance acceptance criteria Δα ≤ 0,05 dB after release, no damage
Short-term crush resistance test method IEC 60794-1-21:E3A
Impact resistance 10 Nm, 3 impacts, d=20 mm, R=300 mm
Impact resistance acceptance criteria Δα ≤ 0,05 dB after test, no damage
Impact resistance test method IEC 60794-1-21:E4
Torsion L = 1 m, rotation angle ±180°, 10 cycles
Torsion acceptance criteria no damage
Torsion test method IEC 60794-1-21:E7
Repeated bending R=10 x cable diameter, 25 cycles, m = 4Kg
Repeated bending acceptance criteria no damage
Repeated bending test method IEC 60794-1-21:E6
Cable bend d=20 x cable diameter, 4 turns, 3 cycles
Cable bend acceptance criteria Δα ≤ 0,05 dB after test, no damage
Cable bend test method IEC 60794-1-21:E11A
Minimum bend radius in service 100 mm
Minimum bend radius during installation 140 mm
Environmental Characteristics
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling acceptance criteria Δα ≤ 0,05 dB
Temperature cycling test method IEC 60794-1-22:F1
Reversible temperature cycling -25 °C +70 °C / -13 °F +158 °F
Reversible temperature cycling acceptance criteria Δα ≤ 0,15 dB, reversible
Reversible temperature cycling test method IEC 60794-1-22:F1
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Storage / Transport temperature -25 °C to +70 °C / -13 °F to +158 °F
Water penetration L = 3 m, h = 1 m, 24 h
Water penetration acceptance criteria no water leakage
Water penetration test method IEC 60794-1-22:F5B
Thermal load 0.63 MJ/m
Flammability vertical single cable Pass
Flammability vertical single cable test method IEC 60332-1-2
Smoke density Pass
Smoke density test method IEC 61034-2
Halogen free, acid gases Pass
Halogen free, acid gases test method IEC 60754-2
2015 / 863 / EU - RoHS 3 conform